This package installs the software (Intel SATA Controller AHCI Driver) to enable the following device. Device Name - Standard SATA AHCI Controller Device name in the Device Manager - Intel(R) 7 Series Chipset Family SATA AHCI Controller. Looking for support on Sony Electronics products? Find firmware updates, software and driver downloads.

What is CipherShield Smart Insert technology?
Smart Insert with CipherKey allows you to have total control of your data with two intelligent key insertion modes. Standard design with all CipherShield drives, mode 0 with hotplug mechanism enables you to authenticate and access the drive when the CipherKey is plugged in. When the key is removed, all data within the drive are encrypted. Mode 1 is better utilized for a large data backup job where you don’t want to be tied waiting for the data transfer to be completed. The CipherShield drive is authenticated by plugging the key in once and removed. The drive runs without the need to have the key connected at all times. The risk of theft is no longer a concern because when a USB or power cable is unplugged, the drive will automatically lock down its content. A limited number of models available, the rest can be special ordered from Buslink, or specify the key mode 1 when ordering from resellers or your preferred IT solution providers.

How to operate the drive?
All CipherShield drives utilize a CipherKey or two CipherKeys to gain access to the drive. Access to the drive is granted by inserting the key into a slot on the faceplate. By removing the key, data cannot be accessed even though the drive is still connected to the computer. When the key is removed, the drive is “transparent” to the operating system of a computer, thereby ensuring full protection of the data.

What is CipherKey, and how does it protect the CipherShield drive?
The CipherKey is a physical key with a design based on the Firewire form factor. It contains the secret encryption key code necessary for encryption and decryption operations. The hard drive has been partitioned and formatted using the CipherKey, thus the entire content of the hard drive is associated only with this unique key. Only a CipherKey containing the identical secret encryption key code can be used for authentication or to unlock the drive.

Why should I need CipherShield encrypted drive?
The sensitive nature of confidential information is driving the need to secure data stored on all portable computer systems. CipherShield’s innovative solution ensures multi-level privacy, confidentiality, and authentication – allowing organizations to protect valuable assets, credentials, and intellectual property that are exposed to significant risk of theft. Legal liability and the financial consequences associated with stolen confidential information require organizations to go to extreme lengths to protect their data. CipherShield encrypted storage products offer superior hardware-based encryption and pre-boot authentication, thus allowing companies to shield their data and regulate control over access to their corporate and sensitive customers information. By doing that, they comply with federal regulations such as Sarbanes-Oxley, or HIPAA (Health Insurance Portability and Accountability Act) for the healthcare industry.

Why hardware encryption is better than software-based encryption?
The encryption strength of the software-based / password protection approach depends entirely on the strength/unguessability of the password itself. Not only that, you have to take into consideration the fact that…. people just forget. With today’s hectic life, remembering a complex password like “Myd0g$N4me#7” with all the numbers, punctuations, and mixed uppercase and lowercase letters, will eventually lead to the password in a post-in note and stuck somewhere to the wall, or else they’re just going to create a simple password like “john123”. And then think about the scenario when the user does forget. With hardware-based key encryption, the key itself is the password. The encryption and decryption, which utilize a government-grade AES encryption algorithm, are done by a processor embedded inside. The access to the data doesn’t rely on a password, which could be easily hacked, but on a physical element.

Apart from a faster, real-time processing of data encryption and decryption, hardware-based encryption is also not as vulnerable as software-based password input in terms of brute force attack of password guessing. An attacker can plug the drive into the computer and have a program performs hundreds of password guessing in a second. Furthermore, there will also a cross-platform issue with the software-based password feature, in which it will only work in Windows PC, not Mac or Linux. With hardware-based encryption, this won’t be an issue at all. The main advantage to CipherShield over other security methods is that our product is designed to be used by everyone and anyone. Unlike software encryption, there are no passwords to remember or complex installation. Such methods usually require MIS support and are quite expensive to maintain.

File system formats explained

There are many types of file system used to store data on drives. The types depend on the operating system (OS) used. Microsoft Windows supports FAT, FAT32, NTFS, and exFAT. Macintosh supports FAT32, HFS+, exFAT, and NTFS (read-only). Linux supports: Ext4, ZFS, xfs, NTFS (need to enable support), and exFAT (need to enable support). It is best to use the native format for better security, compatibility, and speed, i.e. NTFS for Windows, Mac OS Extended (Journaled) for Macintosh, and Ext4 for Linux. If you need to use your drive in multiple OS, reformat your drive to exFAT. All our drives with USB-C come with exFAT as the default format so you can use it in all the OS.

Driver Download

The model number of all BUSlink hard drives are located at the back panel of the unit, where all the power and interface ports are. If you have any questions or difficulty in downloading the files, please contact us at [email protected]

BUSlink USB 3.0 SuperSpeed PCI-Express Card (U3-PCIE)
Drive: USB3-PCIE.zip

L and D series USB 1.1 hard drives ( with yellow panel )

Please note that we no longer provide phone support for L, D, or P series hard drive.

Power adapter: DC output 12V – 2.5A
Driver: 3in1.exe
Alternate Driver: setup2000.exe

  • Only use setup2000.exe if 3in1.exe does not work
  • For Windows 98SE / ME / 2000 / XP SP1 and SP2 only
  • Will not work with Windows XP SP 3, Windows Vista, and Windows 7

Note: We have discontinued support for L and D series hard drives, including any updates for the drivers. If you’re on Windows XP SP3 and above, the only option is to remove the IDE hard drive from the case and plug directly to your PC, or purchase a USB to IDE adaptor, or purchase a new USB 2.0 enclosure. Please email [email protected] for a current list of product examples.

Buslink USB 2.0 External Hard Drive (UII-xxx)
BUSlink Combo USB 2.0 and FireWire External Hard Drive (CO-xxx-U2FE)
BUSlink Triple Interface External Hard Drive (CO-xxx-U2FS)
Disk-On-The-Go USB 2.0 (D-xx-U2)
Disk-On-The-Go Lite Dual Interface USB 2.0 and FireWire (DL-xx-U2F)
Disk-On-The-Go Lite USB 2.0 (DL-xx-U2)
Power adapter for desktop drive: DC output 12V – 2A
Power adapter for Slim drive: DC output 7.5V – 1.2A
Driver: USB2MassStorage_v1019.zip

Hard disk controller driver
  • All these models are plug and play.
  • The mass storage driver is built in on most OS.
  • You only need to install the driver if the computer is still on Windows 98SE.


All FireWire drives including FireWire Data Bankers and Disk-On-The-Go external notebook drives are plug and play.
There is no separate driver available, and none is needed.

  • FireWire Drive with 1 FireWire port will not work with OS X

Power adapter for Desktop Optical Drive: DC output 12V – 2A
Power adapter for Slim Optical Drive: DC output 7.5-1.2A
Driver: USB2MassStorage_v1019.zip

Smart Link Hard Disk Controller Driver In Das Architecture Is Replaced In San Either With

  • All BUSlink External Optical Drives are plug and play, especially those models that start with UII-xx, and those with D-xx-U2 on slimline drives
  • The mass storage driver is built-in on most OS.
  • You only need to install the driver if the computer is still on Windows 98SE.
Smart Link Hard Disk Controller Driver

Cd-rom Controller

BUSlink USB 2.0 PCI Card (UII-PCIP)
BUSlink USB 2.0 and FireWire PCI Card (PCI-U2F)
BUSlink USB 2.0 Cardbus (UII-CB4)
BUSlink USB 2.0, FireWire, and SATA Combo PCI Card (PCI-U2FS)
Driver: U2V2_1_4.zip
SATA Driver for BUSlink USB 2.0, FireWire, and SATA Combo PCI Card (PCI-U2FS): sata_PCI.zip

BUSlink 2 ports SATA Cardbus (CB2S)
Driver: sata_cardbus.zip

Smart Link Hard Disk Controller Driver Usb

Printable version

* RECOMMENDED * HPE Dynamic Smart Array B120i/B320i SATA RAID Controller Driver for 64-bit Microsoft Windows Server 2012/2016 Editions

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Driver - Storage
Version:62.16.0.64(A)(11 Aug 2017)
Operating System(s):
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2012
File name:cp033111.exe (1.3 MB)
This driver provides Microsoft Windows Server 2012, 2012 R2 64-bit and 2016 support for: HPE Dynamic Smart Array B320i Controller. HPE Dynamic Smart Array B120i Controller.

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

9ce40d30153fcd72d5085ad2c0b090708c7daa411f5c862f900139f278ca36accp033111.exe

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Place the Smart Component in a temporary directory, then double-click it to run.

Select 'Install' to start extracting to a temporary location on the hard drive.

Click the 'Install' button to perform the driver installation.

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)

Version:62.16.0.64(A) (11 Aug 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)

Added support for Microsoft Windows Server 2016.


Version:62.16.0.64 (23 Sep 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

REMOVED: Hpsa driver version 62.16.0.64 is NO LONGER AVAILABLE for download due to incorrect reboot instructions. Click the “Obtain software” link to open the HPE Support Center web page for the replacement version 62.16.0.64 (A).

Fixes included in version 62.16.0.64:

  • Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)

Enhancements included in version 62.16.0.64:

  • Added support for Microsoft Windows Server 2016.

Version:62.14.0.64 (1 Apr 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

The following issue is now resolved:

Intermittent blue screen 0x133 (DPS_WATCHDOG_VIOLATION) error would display and the system would stop responding. This error was caused by a race condition that was exposed under particular IO patterns for controllers with write cache enabled.


Version:62.12.0.64 (30 Mar 2015)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Fixes issue with SCSI Verify that can cause bug check.
  • Fixes issue where newer, larger drives may not show up during hot add.
  • Fixes potential data mismatch to RAID5 volumes when read cache is enabled and physical drive fails.

Version:62.10.0.64 (13 Mar 2014)

Upgrade Requirement:
Critical - HP requires users update to this version immediately.

Fix for CA referenced below titled “SPP HOT FIX - HP ProLiant Servers: HP Dynamic Smart Array B120i/B320i Controllers - DRIVER UPGRADE REQUIRED to Ensure That a Drive Array Rebuild Does Not Target an Incorrect Drive and Cause Incorrect Data to Be Written to the Drive”
http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04141183


Version:62.8.0.64 (10 Jan 2014)

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • For the HP Dynamic Smart Array (B120i/B320i) controllers when running Microsoft Windows Server 2012 R2, corrected potential blue screen when using the Microsoft Windows Server 2012 62.6.2.64 (or earlier) version of hpsa2 driver.
  • For systems with a FBWC and HP Dynamic Smart Array B120i/B320i controllers, fixed an issue involving crash dump and cache flush. In the case where a server failure occurs, and a crash dump is generated, in some cases the FBWC was not flushing before the crash dump is written to the disk. Please find customer advisory at http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04045904
  • Added support for Microsoft Windows Server 2012 R2.
  • New enhancements for SCSI Verify commands.

Version:62.6.2.64 (10 Sep 2013)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

New support for the following servers

  • HP ProLiant DL320e Gen8 v2 Server
  • HP ProLiant ML310e Gen8 v2 Server
  • HP ProLiant MicroServer Gen8
  • HP ProLiant SL210t Gen8 Server

Version:62.6.0.64 (19 Feb 2013)

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

  • Resolved intermittent issues seen while burning to optical devices connected to B120i

Version:62.4.0.64 (A) (26 Oct 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Support for Microsoft Windows Server 2012
Support for Microsoft Windows Server 2012 Essentials


Type:Driver - Storage
Version:62.16.0.64(A)(11 Aug 2017)
Operating System(s):
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016

Description

This driver provides Microsoft Windows Server 2012, 2012 R2 64-bit and 2016 support for: HPE Dynamic Smart Array B320i Controller. HPE Dynamic Smart Array B120i Controller.

Enhancements

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

9ce40d30153fcd72d5085ad2c0b090708c7daa411f5c862f900139f278ca36accp033111.exe

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Place the Smart Component in a temporary directory, then double-click it to run.

Select 'Install' to start extracting to a temporary location on the hard drive.

Click the 'Install' button to perform the driver installation.

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)

Revision History

Version:62.16.0.64(A) (11 Aug 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)

Added support for Microsoft Windows Server 2016.


Version:62.16.0.64 (23 Sep 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

REMOVED: Hpsa driver version 62.16.0.64 is NO LONGER AVAILABLE for download due to incorrect reboot instructions. Click the “Obtain software” link to open the HPE Support Center web page for the replacement version 62.16.0.64 (A).

Fixes included in version 62.16.0.64:

  • Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)

Enhancements included in version 62.16.0.64:

  • Added support for Microsoft Windows Server 2016.

Version:62.14.0.64 (1 Apr 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

The following issue is now resolved:

Intermittent blue screen 0x133 (DPS_WATCHDOG_VIOLATION) error would display and the system would stop responding. This error was caused by a race condition that was exposed under particular IO patterns for controllers with write cache enabled.


Version:62.12.0.64 (30 Mar 2015)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Fixes issue with SCSI Verify that can cause bug check.
  • Fixes issue where newer, larger drives may not show up during hot add.
  • Fixes potential data mismatch to RAID5 volumes when read cache is enabled and physical drive fails.

Version:62.10.0.64 (13 Mar 2014)

Upgrade Requirement:
Critical - HP requires users update to this version immediately.

Fix for CA referenced below titled “SPP HOT FIX - HP ProLiant Servers: HP Dynamic Smart Array B120i/B320i Controllers - DRIVER UPGRADE REQUIRED to Ensure That a Drive Array Rebuild Does Not Target an Incorrect Drive and Cause Incorrect Data to Be Written to the Drive”
http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04141183


Version:62.8.0.64 (10 Jan 2014)

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • For the HP Dynamic Smart Array (B120i/B320i) controllers when running Microsoft Windows Server 2012 R2, corrected potential blue screen when using the Microsoft Windows Server 2012 62.6.2.64 (or earlier) version of hpsa2 driver.
  • For systems with a FBWC and HP Dynamic Smart Array B120i/B320i controllers, fixed an issue involving crash dump and cache flush. In the case where a server failure occurs, and a crash dump is generated, in some cases the FBWC was not flushing before the crash dump is written to the disk. Please find customer advisory at http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04045904
  • Added support for Microsoft Windows Server 2012 R2.
  • New enhancements for SCSI Verify commands.

Version:62.6.2.64 (10 Sep 2013)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

New support for the following servers

  • HP ProLiant DL320e Gen8 v2 Server
  • HP ProLiant ML310e Gen8 v2 Server
  • HP ProLiant MicroServer Gen8
  • HP ProLiant SL210t Gen8 Server

Version:62.6.0.64 (19 Feb 2013)

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

  • Resolved intermittent issues seen while burning to optical devices connected to B120i

Version:62.4.0.64 (A) (26 Oct 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Support for Microsoft Windows Server 2012
Support for Microsoft Windows Server 2012 Essentials


Smart Link Hard Disk Controller Driver

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Coments are closed